Part Number Hot Search : 
A2168 SR3040R 5KE13CA V30LL TA1015A A2168 AKD43 8TRPB
Product Description
Full Text Search
 

To Download DQ61212QMA06 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Technical S pecification
DQ61212QMA06
48V in
Input
+/-12V
Outputs
60 Watt
Power
2000Vdc
Isolation
Quar ter-brick
DC/DC Conver ter
Th e DQ 6121 2QM A06 D ua lQ or TM Me g a se ri e s i s a du al o ut p u t co nv er t er t h at us es th e ind u st r y s t an d ar d q u ar t er b r ick p a ckage siz e. Th e ver y high efficie ncy is a re su lt o f S yn Q or 's p aten ted top ol ogy tha t u se s sy nc hr on ou s re ctifica tio n an d an inn ovative co ns tru ction des ign to min imize h eat d is sip a t ion an d al lo w ext r emel y h igh po wer d en s iti es. Th e p owe r d is si pa ted b y th e c onver ter is so l ow th at a h ea tsin k is no t r eq ui red , whi ch s aves cos t, weigh t, h eigh t, an d a p pl i c at io n e ffor t . A ll of t h e p owe r a n d con t ro l c omp on en ts a r e mo u nted to th e m ul ti-l a yer PCB s ub str a te with h igh -y iel d s ur fa ce mou n t t ech no lo gy, r esu l ti ng in a mor e r el ia bl e p r od uc t . RoHS 5/6 Compliant (see page 15 ). Operational Features
* Very high efficiency, >91% at full rated load current * Delivers up to 60 Watts of output power with minimal derating - no heatsink required * Wide input voltage range: 35V - 75V, with 100V 100ms input voltage transient capability * Fixed frequency switching provides predictable EMI performance * No minimum load requirement means no preload resistors required
Dual Output
DQ61212QMA06 Module
Pr otection Features
* Input under-voltage lockout disables converter at low input voltage conditions * Output current limit and short circuit protection protects converter and load from permanent damage and consequent hazardous conditions * Active back bias limit prevents damage to converter from external load induced pre-bias * Output over-voltage protection protects load from damaging voltages * Thermal shutdown protects converter from abnormal environmental conditions
Mechanical Features
* Industry standard pin-out configuration * Industry standard size: 1.45" x 2.3" (36.8x58.4mm) * Total height less than 0.43" (10.9mm), permits better airflow and smaller card pitch * Total weight: 1.5 oz. (43 g) * Flanged pins designed to permit surface mount soldering (avoid wave solder) using FPiP technique
Safety Features
* 2000V, 30 M input-to-output isolation provides input/output ground separation * UL/cUL 60950-1 recognized (US & Canada), basic insulation rating * TUV certified to EN60950-1 * Meets 72/23/EEC and 93/68/EEC directives which facilitates CE Marking in user's end product * Board and plastic components meet UL94V-0 flammability requirements
Contr ol Features
* On/Off control referenced to input side (positive and negative logic options are available) * Output voltage trim: +10%/-10%, permits custom voltages and voltage margining
Product # DQ61212QMA06 Phone 1-888-567-9596 www.synqor.com
Doc.# 005-2DQ612E Rev. C
01/11/06
Page 1
Technical Specification
MECHANICAL DIAGRAM
2.30
(58.4)
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
0.475
(12.07)
0.38
(9.7)
2.00
(50.8)
0.225
(5.71)
0.14
(3.6)
0.025
(.64)
0.700
(17.78)
Top View
0.725
(18.41)
1.45
(36.8)
0.350
(8.89)
Bottom side Clearance
See Note 8
Side View
0.43
Lowest Component (10.9) Load Board Flanged Pin See Note 9
0.060+/-0.030
(1.52+/-0.76)
0.145
(3.68) See Note 2
NOTES
1) All pins are 0.040" (1.02mm) diameter with 0.080" (2.03 mm) diameter standoff shoulders. 2) Other pin extension lengths available. Recommended pin length is 0.03" (0.76mm) greater than the PCB thickness. 3) All Pins: Material - Copper Alloy Finish - Tin/Lead over Nickel plate 4) Undimensioned components are shown for visual reference only. 5) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 6) Weight: 1.5 oz. (43 g) typical 7) Workmanship: Meets or exceeds IPC-A-610C Class II 8) UL/TUV standards require a clearance greater than 0.04"
(1.02mm) between input and output for Basic insulation. This issue should be considered if any copper traces are on the top side of the user's board. Note that the ferrite cores are considered part of the input/primary circuit.
PIN DESIGNATIONS
Pin No.
1 2 3 4 5 6 7
Name
Vin(+) ON/OFF Vin(-) 12Vout(-) OP RTN TRIM 12Vout(+)
Function
Positive input voltage TTL input to turn converter on and off, referenced to Vin(-), with internal pull up. Negative input voltage 12V negative output voltage Output Return Output voltage trim 12V positive output voltage
9) The flanged pins are designed to permit surface mount soldering (allowing to avoid the wave soldering process) through the use of the flanged pin-in-paste technique.
Product # DQ61212QMA06
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2DQ612E Rev. C
01/11/06
Page 2
Technical Specification
DQ61212QMA06 ELECTRICAL CHARACTERISTICS
Parameter
ABSOLUTE MAXIMUM RATINGS
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
TA=25C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40C to +100C ambient temperature with appropriate power derating. Specifications subject to change without notice.
Min. Typ. Max.
100 80 100 2000 100 125 18 48 33 29.5 3.5 70 2.0 150 175 4.7\2.0 47 -12.06 12.06 75 34 30.5 4.5 2.1 80 5 0.01 20 20
Units
V V V V C C V V V V V A mA mA A 2s mV mA mA A H\F F V V V V mV mV A A A V A mA F dB mV mV s
Notes & Conditions
Continuous Continuous 100ms transient, square wave Basic insulation, Pollution Degree 2
Input Voltage Non-Operating Operating Operating Transient Protection Isolation Voltage (input to output) Operating Temperature Storage Temperature Voltage at ON/OFF input pin Operating Input Voltage Range Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Voltage Hysteresis Maximum Input Current No-Load Input Current Disabled Input Current Inrush Current Transient Rating Response to Input Transient Input Reflected Ripple Current Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) Recommended External Input Capacitance Output Voltage Set Point (-12V) Output Voltage Set Point (+12V) Total Output Voltage Regulation (-12V) Total Output Voltage Regulation (+12V) Output Voltage Ripple and Noise (+12V)1 Peak-to-Peak RMS Operating Output Current Range (+12V) Output DC Current-Limit Inception (+12V) Short-Circuit Protection - redundant shutdown (+12V) Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Input Voltage Ripple Rejection Output Voltage during Load Current Transient For a Step Change in -12V Output Current (.1A/s) For a Step Change in +12V Output Current (.1A/s) Settling Time Turn-On Transient Turn-On Time Start-Up Inhibit Time Output Voltage Overshoot 100% Load 50% Load Semiconductor Junction Temperature Board Temperature Transformer Temperature Isolation Voltage (dielectric strength) Isolation Resistance Isolation Capacitance2
-40 -55 -2 35 32 28.5 2.5
INPUT CHARACTERISTICS
100% Load, 35 Vin
1000V/ms input transient RMS thru 10H inductor; Figures 23 & 25 RMS; Figures 23 & 24 Fast blow external fuse recommended Internal values; see Figure E Typical ESR 0.1-0.2, see Figure 23 48Vin, 50% load on each voltage 48Vin, 50% load on each voltage Cross regulation, line, load, temp; Figures 7 - 10 Cross regulation, line, load, temp; Figures 7 - 10 20MHz bandwidth; Figures 23 & 26 Full Load; see Figures 23 & 26 Full Load; see Figures 23 & 26 Subject to thermal derating; Figures 11 - 18 Output Voltage 10% Low; Figures 27 - 28 Figures 29 - 30 Negative current drawn from output Negative current drawn from output 12Vout at 5A Resistive Load 120 Hz; Figures 33 - 34 50% to 75% to 50% Iout max; Figure 21 50% to 75% to 50% Iout max; Figure 22 To within 1% Vout nom Full load, Vout=90% nom.; Figures 19 & 20 -40C to +125C; Figure F 4,800 F load capacitance, Iout = 0A 48Vin, 50% combined Vout; Figures 1 - 6 48Vin, 50% combined Vout; Figures 1 - 6 Package rated to 150C UL rated max operating temp 130C See Figures 11 - 18 for derating curves
OUTPUT CHARACTERISTICS
-12.60 11.55
-11.55 12.60 180 30 5 6.5 0.90 4,800
0 5.7 0.18
80 12 6 12 8 0.54 10 55 160 160 200
DYNAMIC CHARACTERISTICS
180
4 200 5 91.5 91.5
8 240
ms ms % % %
EFFICIENCY
TEMPERATURE LIMITS FOR POWER DERATING CURVES
125 125 110 2000 30 470
C C C V M pF
ISOLATION CHARACTERISTICS
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com). Note 2: Higher values of isolation capacitance can be added external to the module.
Product # DQ61212QMA06
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2DQ612E Rev. C
01/11/06
Page 3
Technical Specification
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
Min.
185 -2 2.4 2.4 -2
Typ.
200
Max.
215 0.8 18 18 0.8
Units
kHz V V V V V k % V V C C
Notes & Conditions
Regulation stage and Isolation stage
Switching Frequency ON/OFF Control (Option P) Off-State Voltage On-State Voltage ON/OFF Control (Option N) Off-State Voltage On-State Voltage ON/OFF Control (Either Option) Pull-Up Voltage Pull-Up Resistance Output Voltage Trim Range Output Over-Voltage Protection (-12V) Output Over-Voltage Protection (+12V) Over-Temperature Shutdown Over-Temperature Shutdown Restart Hysteresis Calculated MTBF (Telcordia) Calculated MTBF (MIL-217) Field Demonstrated MTBF
-10 -13.7 13.7 117
Vin/6 40 -14.5 14.5 122 10 2.05 2.5
9.2 +10 -15 15 127
Figures A & B
Trim-up pins 6-5, Trim-down pins 6-4 Over full temp range Over full temp range Average PCB Temperature
RELIABILITY CHARACTERISTICS
106 Hrs. TR-NWT-000332; 80% load,300LFM, 40oC Ta 106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40oC Ta 106 Hrs. See website for details
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
Notes
File # E194341, Basic insulation & pollution degree 2 Certified by TUV Test on entire assembly; board & plastic components UL94V-0 compliant ESD test, 8kV - NP, 15kV air - NP (Normal Performance) Section 7 - electrical safety, Section 9 - bonding/grounding
UL/cUL 60950-1 EN60950-1 72/23/EEC 93/68/EEC Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 GR-1089-CORE Telcordia (Bellcore) GR-513
* An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
# Units
32 5 5 10 5 5 5 15 pins
Test Conditions
10-55Hz sweep, 0.060" total excursion,1 min./sweep, 120 sweeps for 3 axis
Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability
95% rated Vin and load, units at derating point, 1000 hours
100g minimum, 2 drops in x and y axis, 1 drop in z axis -40C to 100C, unit temp. ramp 15C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10C to Tmax+10C, 5C steps, Vin = min to max, 0-105% load 85C, 85% RH, 1000 hours, 2 minutes on and 6 hours off MIL-STD-883, method 2003
* Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply robust, reliable product. Contact the factory for official product family qualification documents.
OPTIONS
SynQor provides various options for Logic Sense, Pin Length and Feature Set for this family of DC/DC converters. Please consult the last page of this specification sheet for information on available options.
Product # DQ61212QMA06 Phone 1-888-567-9596
PATENTS
SynQor is protected under various patents, including but not limited to U.S. Patent numbers 5,999,417; 6,222,742 B1; 6,594,159 B2; 6,545,890 B2.
www.synqor.com
Doc.# 005-2DQ612E Rev. C
01/11/06
Page 4
Technical Specification
100 95 90 6 5
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
Power Dissipation (W)
Efficiency (%)
4 3 2
85 80 75 70 65 60 0 12 24 36 48 60 35 Vin 48 Vin 75 Vin
35 Vin
1 0 0 12 24 36 48
48 Vin 75 Vin
60
Total Output Power (W)
Total Output Power (W)
Figure 1: Efficiency vs. output power, from 0 load to full load with 50% load on -12V output and 50% load on +12V output at minimum, nominal, and maximum input voltage at 25C.
100 95 90
Figure 2: Power dissipation vs. output power, from 0 load to full load with 50% load on -12V output and 50% load on +12V output at minimum, nominal, and maximum input voltage at 25C.
6 5
Power Dissipation (W)
Efficiency (%)
4 3 2
85 80 75 70 65 60 34.5/1.2 27.5/8.5 19.2/16.9 10.9/25.2 2.4/33.5 35 Vin 48 Vin 75 Vin
35 Vin
1 0 34.5/1.2 27.5/8.5 19.2/16.9 10.9/25.2 2.4/33.5
48 Vin 75 Vin
Output Power (W), -12Vout/+12Vout
Output Power (W), -12Vout/+12Vout
Figure 3: Efficiency vs. output power, with total output power fixed at 60% load (36W) and loads split as shown between -12V and +12V outputs at minimum, nominal, and maximum input voltage at 25C.
Figure 4: Power dissipation vs. output power, with total output power fixed at 60% load (36W) and loads split as shown between -12V and +12V outputs at minimum, nominal, and max input voltage at 25C.
93
7.0
92
Efficiency (%)
91
Power Dissipation (W)
6.0
5.0
90
4.0 25 C 40 C 55 C 0 100 200 300 400 500
89
88
87 0 100 200 300 400
25 C 40 C 55 C
500
3.0
2.0 Air Flow (LFM)
Air Flow (LFM)
Figure 5: Efficiency vs. load current, with 80% load and 50/50 voltage split (2A load on -12V and 2A load on +12V) over variations in temperature and airflow.
Product # DQ61212QMA06 Phone 1-888-567-9596
Figure 6: Power dissipation vs. load current, with 80% load and 50/50 voltage split (2A load on -12V and 2A load on +12V) over variations in temperature and airflow.
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 5
www.synqor.com
Technical Specification
12.20 12.15 12.10 12.05 VOUT1 (-V) 12.00 11.95 11.90 11.85 11.80 11.75 11.70
60/0 48/12
Input: Outputs: Power: Package:
12.20 12.20 12.15 12.10 12.05 VOUT1 (-V) VOUT2 (V) 12.00 11.95 11.90 11.85 11.90 11.80 12.05 12.00 11.95
35-75V +12V & -12V 60W Quarter-brick
12.20
Input voltage has virtually no effect on cross regulation
12.15 12.10
Input voltage has virtually no effect on cross regulation
12.15 12.10 VOUT2 (V) 12.05 12.00 11.95 11.90
-12V_48Vin +12V_48Vin
36/24 24/36 12/48
11.75 11.70
0/60
11.85 11.80
42/3 35/10
-12V_48Vin +12V_48Vin
25/20 20/25 10/35
11.85 11.80
3/42
POUT1 / POUT2 (W)
POUT1 / POUT2 (W)
Figure 7: Load regulation vs. load current with power fixed at full load (60W) and load currents split as shown between -12V and +12V outputs, at nominal input voltage.
12.20 12.15 12.10 VOUT1 (-V) 12.05 12.00 11.95 11.90 11.85 11.80
12.0 24.0 36.0 48.0
Figure 8: Load regulation vs. load current with power fixed at 75% load (45W) and load currents split as shown between -12V and +12V outputs, at nominal input voltage.
12.20 12.15 12.10 VOUT1 (-V) 12.20
12.20
Input voltage has virtually no effect on cross regulation
12.15 12.10 VOUT2 (V) 12.05 12.00 11.95 11.90
Input voltage has virtually no effect on cross regulation
12.15 12.10 VOUT2 (V) 12.05 12.00 11.95 11.90
12.05 12.00 11.95 11.90 11.85 11.80
12 24 36 48 60
-12V_48Vin +12V_48Vin Total Output Power (W)
11.85 11.80
60.0
-12V_48Vin +12V_48Vin Total Output Power (W)
11.85 11.80
Figure 9: Load regulation vs. output power from 12W load to full load with 75% load on -12V output and 25% load on +12V output at nominal input voltage.
Figure 10: . Load regulation vs. output power from 12W load to full load with 25% load on -12V output and 75% load on +12V output at nominal input voltage.
5.0 4.5 4.0 3.5
Iout (A)
3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 25 40 55
o
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 LFM (0 m/s)
70
85
Ambient Air Temperature ( C)
Semiconductor junction temperature is within 1C of surface temperature
Figure 11: Maximum output power derating curves vs. ambient air temperature for airflow rates of 0 to 400 LFM, air flowing from pin 1 to pin 3. Full load (5A) on -12V output and no load on +12V output.
Product # DQ61212QMA06 Phone 1-888-567-9596
Figure 12: Thermal plot of converter at 5 amp load on -12V output and no load on +12V output with 55C air flowing at 200 LFM. Air flow across the converter is from pin 1 to pin 3 (nominal input voltage)
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 6
www.synqor.com
Technical Specification
5.0 4.5 4.0 3.5
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
Iout (A)
3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 25 40 55 70 85
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 LFM (0 m/s)
Ambient Air Temperature (oC)
Semiconductor junction temperature is within 1C of surface temperature
Figure 13: Maximum output power derating curves vs. ambient air temperature for airflow rates of 0 to 400 LFM, air flowing from pin 1 to pin 3. Full load (5A) on +12V output and no load on -12V output.
2.5
Figure 14: Thermal plot of converter at 5 amp load on +12V output and no load on -12V output with 55C air flowing at 200 LFM. Air flow across the converter is from pin 1 to pin 3 (nominal Vin)
2.0
Iout (A)
1.5
1.0
400 LFM (2.0 m/s) 300 LFM (1.5 m/s)
0.5
200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 LFM (0 m/s)
0.0 0 25 40 55
o
70
85
Ambient Air Temperature ( C)
Semiconductor junction temperature is within 1C of surface temperature
Figure 15: Max output power derating curves vs. air temp for 0 to 400 LFM, pin 1 to pin 3. 50% load (2.5A) on -12V output and 50% load (2.5A) on +12V output. At derating points, +12V output decreases while -12V output remains unchanged.
Figure 16: Thermal plot of converter at 2.5 amp load on -12V output and 2.5 amp load on +12V output with 55C air flowing at 200 LFM. Air flow across the converter is from pin 1 to pin 3 (nominal Vin)
3.5 3.0 2.5
Iout (A)
2.0 1.5 1.0 0.5 0.0 0
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 LFM (0 m/s)
25
40
55
70
85
Ambient Air Temperature (oC)
Semiconductor junction temperature is within 1C of surface temperature
Figure 17: Max output power derating curves vs. air temp for 0 to 400 LFM, pin 1 to pin 3. 30% load (1.5A) on -12V output and 70% load (3.5A) on +12V output. At derating points, +12V output decreases while -12V output remains unchanged.
Product # DQ61212QMA06 Phone 1-888-567-9596
Figure 18: Thermal plot of converter at 3.5 amp load on +12V output and 1.5 amp load on -12V output with 55C air flowing at 200 LFM. Air flow across the converter is from pin 1 to pin 3 (nominal Vin).
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 7
www.synqor.com
Technical Specification
+12Vout
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
+12Vout
-12Vout
-12Vout
Figure 19: Turn-on transient at full rated load current (resistive load) (10 ms/div). Input voltage pre-applied. Ch 1: -12Vout (5V/div); Ch 2: +12Vout (5V/div); Ch 3:ON/OFF input (5V/div).
Figure 20: Turn-on transient at zero load current (10 ms/div). Ch 1: 12Vout (5V/div); Ch 2: +12Vout (5V/div); Ch 3: ON/OFF input (5V/div).
+12Vout +12Iout
+12Vout
-12Vout
+12Iout -12Vout
-12Iout -12Iout
Figure 21: Output voltage response to step-change in Iout1 (50%-75%-50% of Imax; dI/dt = 0.1A/s). Load cap: 15F, 300 m ESR tantalum cap & 1F ceramic cap. Vout (500mV/div), Iout (5A/div). Ch1: Vout1; Ch2 Iout1; Ch 3: Vout2; Ch 4 Iout2
Figure 22: Output voltage response to step-change in Iout2 (50%-75%-50% of
Imax; dI/dt = 0.1A/s). Load cap: 15F, 300 m ESR tantalum cap & 1F ceramic cap.. Vout (500mV/div), Iout (5A/div). Ch1: Vout1; Ch2 Iout2; Ch 3: Vout2; Ch 4 Iout2
See Fig. 25 source impedance
10 H
See Fig. 24
See Fig. 26
VOUT2+
iS
VSOURCE
iC
DC/DC Converter 1 F
VOUT1+
15 F, 300m ESR
tantalum capacitors
47 F, <1 ESR
electrolytic capacitor
ceramic capacitors
COM (-)
Figure 23: Test set-up diagram showing measurement points for Input Terminal Ripple Current (Figure 24), Input Reflected Ripple Current (Figure 25) and Output Voltage Ripple (Figure 26).
Product # DQ61212QMA06 Phone 1-888-567-9596
Figure 24: Input Terminal Ripple Current, -12V & +12V outputs at 50% rated output current and nominal input voltage with 10H source impedance and 100F electrolytic capacitor (200 mA/div). (see Fig. 23)
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 8
www.synqor.com
Technical Specification
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
+12Vout
-12Vout
Figure 25: Input reflected ripple current, is, through a 10 H source inductor at nominal input voltage and rated load current (5 mA/div). -12V and +12V outputs at 50% rated load current. (see Fig. 23)
Figure 26: Output voltage ripple at nominal input voltage and 50% rated load current on both outputs (10 mV/div). Load capacitance: 1F ceramic cap & 15F tantalum cap. Bandwidth: 20 MHz. (see Fig. 23)
15.0
15.0 14.0 13.0
Output Voltage (-V)
14.0 13.0 Output Voltage (+V) 12.0 11.0 10.0 9.0 8.0 7.0 6.0
2.0 3.0 4.0 5.0 6.0 7.0
12.0 11.0 10.0 9.0 8.0 7.0 6.0 5.0 0.0 1.0
Load Current (A)
35 V 48 V 75 V
35 V 48 V 75 V 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
5.0 Load Current (A)
Figure 27: Output voltage vs. load current showing typical current limit curves and converter shutdown points for the -12V output. +12V load is at 0A.
Figure 28: Output voltage vs. load current showing typical current limit curves and converter shutdown points for the +12V output. -12V load is at 0A.
Figure 29: Load current for -12V output (2A/div) as a function of time when the converter attempts to turn on into a 10 m short circuit. Top trace is an expansion of the on-time portion of the bottom trace.
Product # DQ61212QMA06 Phone 1-888-567-9596
Figure 30: Load current for +12V output (2A/div) as a function of time when the converter attempts to turn on into a 10 m short circuit. Top trace is an expansion of the on-time portion of the bottom trace.
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 9
www.synqor.com
Technical Specification
1 1
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
Output Impedance ( )
0.1 36 Vin 48 Vin 75 Vin 0.01
Output Impedance ( )
0.1 36 Vin 48 Vin 75 Vin 0.01
0.001 10 100 1,000 10,000 100,000
0.001 10 100 1,000 10,000 100,000
Hz
Hz
Figure 31: Output impedance (Zout1 = Vout1/Iout1) for minimum, nominal, and maximum input voltage at full rated power, for -12V output.
Figure 32: Output impedance (Zout2 = Vout2/Iout2) for minimum, nominal, and maximum input voltage at full rated power, for +12V output.
0 -10
Forward Transmission (dB) Forward Transmission (dB)
0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 10 100 1,000 10,000 100,000 10 100 1,000 10,000 100,000 36 Vin 48 Vin 75 Vin
-20 -30 -40 -50 -60 -70 -80 -90 -100 -110 36 Vin 48 Vin 75 Vin
Hz
Hz
Figure 33: Forward Transmission (FT1 = Vout1/Vin) for minimum, nominal, and maximum input voltage at full rated power, for -12V output.
Figure 34: Forward Transmission (FT2 = Vout2/Vin) for minimum, nominal, and maximum input voltage at full rated power, for +12V output.
10 0
Reverse Transmission (dB)
10 0
Reverse Transmission (dB)
-10 -20 -30 -40 -50 -60 10 100 1,000 10,000 100,000 36 Vin 48 Vin 75 Vin
-10 -20 -30 -40 -50 -60 10 100 1,000 10,000 100,000 36 Vin 48 Vin 75 Vin
Hz
Hz
Figure 35: Reverse Transmission (RT1 = Iin/Iout1) for minimum, nominal, and maximum input voltage at full rated power, for -12V output.
Product # DQ61212QMA06 Phone 1-888-567-9596
Figure 36: Reverse Transmission (RT2 = Iin/Iout2) for minimum, nominal, and maximum input voltage at full rated power, for +12V output.
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 10
www.synqor.com
Technical Specification
100
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
Input Impedance ( )
10 36 Vin 48 Vin 75 Vin 1
0.1 10 100 1,000 Hz 10,000 100,000
Figure 37: Input impedance (Zin = Vin/Iin) for minimum, nominal, and maximum input voltage at full rated power.
Product # DQ61212QMA06
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2DQ612E Rev. C
01/11/06
Page 11
Technical Specification
BASIC OPERATION AND FEATURES
The DualQor series converter uses a two-stage power conversion topology in which the two output voltages are cross regulated. The first stage is a buck-converter that keeps the output voltage constant over variations in line, load, and temperature. The second stage uses a transformer to provide the functions of input/output isolation and voltage step-down to achieve the low output voltage required. The two-stage solution is ideal for converters with multiple crossregulated output voltages. The first-stage compensates for any variations in line voltage. Therefore, the dependence of the output voltage on line variations is minimized. Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer's output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the DualQor series of converters has such high efficiency, even at very low output voltages and very high output currents. Dissipation throughout the converter is so low that it does not require a heatsink for operation. However, baseplated versions
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
The DualQor has many standard control and protection features. All shutdown features are non-latching, meaning that the converter shuts off for 200 ms before restarting (see Figure F).
CONTROL FEATURES
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). There are two versions of the converter that differ by the sense of the logic used for the ON/OFF input. In the positive logic version, the ON/OFF input is active high (meaning that a high turns the converter on). In the negative logic version, the ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details five possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/OFF circuitry. OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage up or down according to the trim range specifications. It is important to recognize that adjusting one output will also adjust the second output proportionally. To lower the output voltage, the user should connect a resistor between Pin 6 and Pin 7. To raise the output voltage, the user should connect a resistor between Pin 6 and Pin 5. The following table shows the resistor values needed to trim the output voltVo(%) 1 2 3 4 5 6 7 8 9 10 R up 397 178 105 68.4 46.5 31.9 21.5 13.65 7.57 0 R down 466 208 121.5 78.4 52.7 35.4 23.1 13.87 6.7 0
are available for optional heatsinking in severe thermal environments. The DualQor series converter uses the industry standard footprint and pin-out configuration.
ON/OFF
ON/OFF
ON/OFF
Vin(_) Remote Enable Circuit
Vin(_) Negative Logic (Permanently Enabled) ON/OFF
TTL/ CMOS
Vin(_) Positive Logic (Permanently Enabled)
Vin(+)
274k ON/OFF 50k
5V
5V ON/OFF
TTL
100pF 50k
Vin(_) Open Collector Enable Circuit
Vin(_) Direct Logic Drive
Vin(_)
Figure A: Various circuits for driving the ON/OFF pin.
Product # DQ61212QMA06 Phone 1-888-567-9596 www.synqor.com
Figure B: Internal ON/OFF pin circuitry
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 12
Technical Specification
age up or down. Resistor values in Kohms for the desired increase/decrease (typical) in output voltage (%) Note: The TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. Total DC Variation of Vout: For the converter to meet its full specifications, the maximum variation of the DC value of Vout, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range.
Input: Outputs: Power: Package:
35-75V +12V & -12V 60W Quarter-brick
cycle until the short circuit condition is removed. This prevents excessive heating of the converter or the load board. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-Temperature Shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the OverTemperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value.
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled "Input System Instability" on our web. The lockout circuitry is a comparator with DC hysteresis. When the input voltage is rising, it must exceed the typical Turn-On Voltage Threshold value (listed on the specification page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance of the short across the output is small enough to make the output voltage drop below the specified Output DC Current-Limit Shutdown Voltage, the converter turns off. The converter then enters a "hiccup mode" where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5% duty
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because any DC/DC converter appears incrementally as a negative resistance load. A detailed application note titled "Input System Instability" is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. Application Circuits: Figure D below provides a typical circuit diagram which details the input filtering and voltage trimming.
Vin(+)
External Input Filter Electrolytic Capacitor 47F
-12 Vout(-) Trim
Rtrim-up Cload
or
Iload
Vin
ON/OFF
OP RTN
Rtrim-down Vin(_) +12 Vout(+)
Cload Iload
Figure D: Typical application circuit (negative logic unit, permanently enabled).
Product # DQ61212QMA06 Phone 1-888-567-9596 www.synqor.com Doc.# 005-2DQ612E Rev. C 01/11/06 Page 13
Technical Specification
Input Filtering and External Capacitance: Figure E provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the "Input Characteristics" section. More detailed information is available in the application note titled "EMI Characteristics" on the SynQor website.
Vin(+)
Input: Outputs: Power: Package:
L
35-75V +12V & -12V 60W Quarter-brick
C Vin(_)
Figure E: Internal Input Filter Diagram (values listed on page 3).
Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for at least 200ms when it is shut down for any reason. When an output short is present, this generates a 5Hz "hiccup mode," which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: * Input Under-Voltage Lockout * Input Over-Voltage Shutdown (not present in Quarter-brick) * Output Over-Voltage Protection * Over Temperature Shutdown * Current Limit * Short Circuit Protection * Turned off by the ON/OFF input Figure F shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2:
Vin
Under-Voltage Lockout Turn-On Threshold
Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. When the ON/OFF pin goes high after t2, the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time.
ON/OFF
(pos logic)
ON
OFF ON
OFF
ON
4ms (typical
Vout
turn on time)
200ms
(typical start-up inhibit period)
200ms
200ms
t0
t1
t2
t
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # DQ61212QMA06 Phone 1-888-567-9596 www.synqor.com Doc.# 005-2DQ612E Rev. C 01/11/06 Page 14
Technical Specification
PART NUMBERING SYSTEM
The part numbering system for SynQor's DualQor DC/DC converters follows the format shown in the example below.
DQ 6 12 12 Q M A 06 N K S Options (see Ordering Information) Output Power Thermal Design/Profile Performance Level Package Size Output Voltage 2 Output Voltage 1 Input Voltage Product Family
Input: Outputs: Power: Package:
ORDERING INFORMATION
35-75V +12V & -12V 60W Quarter-brick
The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional 3 characters for options.
Model Number DQ63318QMA04xyz DQ63325QMA04xyz DQ65033QMA06xyz DQ61212QMA06xyz Input Voltage 35 - 75 V 35 - 75 V 35 - 75 V 35 - 75 V Output Max Output Voltages Power 3.3/1.8 V 40 W 3.3/2.5 V 40 W 5.0/3.3 V 60 W +12/-12 V 60 W
The following option choices must be included in place of the x y z spaces in the model numbers listed above.
Options Description: x y z
Pin Length K - 0.110" P - Positive N - 0.145" N - Negative R - 0.180" Y - 0.250" Enable Logic Feature Set S - Standard
The first 12 characters comprise the base part number and the last 3 characters indicate available options. Although there are no default values for enable logic and pin length, the most common options are negative logic and 0.145" pins. These part numbers are more likely to be readily available in stock for evaluation and prototype quantities.
Application Notes
A variety of application notes and technical white papers can be downloaded in pdf format at www.synqor.com.
RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. SynQor products are currently 5/6 RoHS compliant with lead being the exception. For more information please visit our RoHS Compliance / Lead Free Initiative web page or e-mail us at rohs@synqor.com.
Contact SynQor for further information:
Phone: Toll Free: Fax: E-mail: Web: Address:
978-849-0600 888-567-9596 978-849-0602 power@synqor.com www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA
Phone 1-888-567-9596
Warranty SynQor offers a three (3) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor.
Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor.
Doc.# 005-2DQ612E Rev. C 01/11/06 Page 15
Product # DQ61212QMA06
www.synqor.com


▲Up To Search▲   

 
Price & Availability of DQ61212QMA06

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X